Homa T-motor voltage change Manuel d'utilisateur Page 2

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 2
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 1
7. Re-connect the wires as seen in
(Fig. 4).
8. Separate the wire bundle with wire
number 2 and re-connect as seen in
(Fig 4).
9. Separate the wire bundle with wire
number 3 and re-connect as seen in
(Fig 4).
Fig. 4
10. Double-check all wires have been
connected correctly.
11. Gently tuck wire bundles behind stator
windings, being certain nothing
extends below the motor housing.
(Fig. 5)
12. Place wavy washer back on top of
upper bearing and verify large motor
housing o-ring is positioned in its
groove.
13. Slowly and carefully lower motor
housing onto pump (DO NOT ALLOW
ROTOR TO SCRUB AGAINST
STATOR.) For T-motors, re-connect
seal probe.
Fig. 5
14. Re-attach motor housing to volute with
cap screws.
15. Record voltage change in pump
service manual.
16. Pump is now ready to operate.
Publication
88FN2046A
Please Contact Technical Support At 203-736-8890 With Any Additional Questions
Please Be Prepared To Provide Pump Serial Number During Call
Page
2 of 2